Section 2: System Archtecture - Honeywell Galaxy Dimension Series Installer Manual

Hide thumbs Also See for Galaxy Dimension Series:
Table of Contents

Advertisement

Galaxy Dimension Installer Manual

SECTION 2: SYSTEM ARCHTECTURE

PSTN (comm 1)
Audio Interface
Module (1)
RS232
Serial Port
(comm 6)
RS485 line
*
NOTE:
Valid addresses for the
keyprox are:
Line 1 (0, 1 & 2).
Line 2 (0, 1, 2, & 3 ).
This sets the address for both
the keypad and card reader
parts of the keyprox.
*
Certain keypad and
max addresses can
be replaced by a
combined keyprox unit.
NOTE:
RIOs, RF RIO's and
PSU's can be mixed on
the lines.
Power Unit P025
Power RIO P026
NOTE:
The Telecom, Printer Interface,
RS232, Ethernet and ISDN
modules can only be
connected to line 1.
If a Telecom module is attached,
keypad address E cannot be
connected to line 1(address E is
shown as 18 on the system).
If an RS232 module is attached,
keypad address D cannot be
connected to line 1 (address D is
shown as 17 on the system).
If an Ethernet module is attached,
keypad address B cannot be
connected to line 1 (address B is
shown as 15 on the system).
If an ISDN module is attached,
keypad address C cannot be
connected to line 1 (address C is
shown as 16 on the system).
16 zones on board
on board
Galaxy
8 outputs
telecom
Trigger
on board
area
Header
plus 6 outputs
on trigger header
Line
Line
Line
Line
1
2
3
4
Lines 2, 3 and 4 have
the same configuration
Cable run 1 km (max)
*
Keypads
CP027/
Keyprox
CP028
4 outputs
RIO
C072
8 zones
OR
4 outputs
Smart PSU
P015
8 zones
OR
4 outputs
or
8 zones
OR
RF RIO Module
C076
Telecom Module
E062 (comm 5)
RS232 Module
E054 (comm 2)
ISDN Module
E077 (comm 3)
Ethernet Module
E080 (comm 4)
Printer Interface
A134/A161
Figure 2-1. Galaxy Dimension System Configuration
Touch
Center
CP040
*
Max
MX03
OR
OR
DCM
C080/81
4 outputs
8 zones
4 outputs
8 zones
4 outputs
8 zones
Twisted Pair
Screened Cable
GD-48
Lines
Keypads
Keyproxes
Touch Center
MAX's
DCM's
RIO's/PSU's
2-1
Configuration
*
Keypads
CP027/
Keyprox
CP028
Touch
Center
CP040
*
Max
MX03
DCM
C080/81
RIO
C072
OR
Smart PSU
P015
OR
Power Unit P025
or
Power RIO P026
OR
RF RIO Module
C076
GD-96
GD-264
1
2
2
8
8 per line
8 per line
3
3 (line 1)
3 (line 1)
4 (line 2)
4 (line 2)
1
1 per line
1 per line
4
8 per line
8 per line
4
8 per line
8 per line
4
4 (line 1)
15 (line 1)
6 (line 2)
16 (line 2)
GD-520
4
8 per line
3 (line 1)
7 (lines 2, 3, 4)
1 per line
8 per line
8 per line
15 (line 1)
16 (lines 2, 3, 4)