Display Options

Option 21 – Display Zones (Quick Menu Option 3)
Selecting and entering the Display Zones option shows the first zone on the system. Other zones may be
viewed by pressing the A and B keys or by entering the zone number directly.
The top line displays:
the address;
the group assigned — if the group mode is enabled. Only the zones assigned to the user's group are
displayed.
the zone function alternating with the status — open, closed, high resistance, low resistance, tamper short
or tamper open circuit or masked.
The bottom line shows:
the zone descriptor (if used);
by pressing the # key the bottom line changes to show the circuit resistance in Ohms, if using a hardwired
RIO and the RIO (not zone) voltage, pressing the # key returns the bottom line to the zone descriptor.
Pressing the # key twice gives the maximum (+) and minimum (-) zone resistance for a particular day. The
scroll keys (A & B) scrolls between the stored values for the past 14 days.
A printout of all the zones is available from this option by pressing the
printout.
NOTE: A serial printer must be connected to the Galaxy panel via a printer interface module, an RS232
interface module, or the on-board RS232 serial port.
21 - Display Zones
key; pressing the esc key aborts the