53 - Program Outputs (cont'd)
Link outputs can be activated by any of the link option sources. The operation of the Link output is depend-
ent on the Output Mode and Groups assigned to the output. The Groups assigned to the Link must have at
least one group common to the link output, if that output is to be activated. This feature can be used to multi-
ply the number of different link outputs available on the system.
NOTE: When a zone function is the source of a Link output type, then a point to point link is available and
is as effective as direct wiring.
66 RF Jam (Latch)
The RF Jam output is activated whenever any of the RF RIO's configured onto the system detect a significant
level of interference to cause radio jamming.
67 RF Super (Latch)
The RF Supervision output is activated whenever there is a supervision failure from any one of the super-
vised RF detectors configured onto the system. That is, when the system has received no signals (including
periodic check-in signals) whatsoever, from a particular detector within the programmed supervision period.
68 Bell Fail
The Bell Fail output activates whenever a zone causes a fault condition.
69 Low Volts
The Low Volts output activates when the voltage of the AUX outputs drops below 10V.
70 Lockout (Reflex)
The Lockout output is active between the ON and OFF times assigned to the Lockout Status (option
65.3.6=TIMERS.Autoset.Lockout Status). The Lockout output mode is Reflex, therefore it remains
active until the lockout switches OFF.
71 Vibration Test (Pulse)
The Vibration Test function is used to test zones programmed as Vibration. This output is used in conjunc-
tion with Precheck (menu option 66 – Pre-Check: - Mode: 4 – Forced Check). The Vibration Test output
sends a five second positive removed pulse to the vault sensors. Any sensor not activated by the test is re-
ported by the pre-check function and prevents the system from setting.
72 – 75 ATM-1, ATM-2, ATM-3, ATM-4 (Reflex)
The relevant ATM output is activated when the respective ATM zone type is omitted. This output is a Reflex
output and follows the omit status of the ATM zone types.
76 Fault (Latch)
This output will activate any time there is a fault condition present on the panel and will clear when all the fault
conditions have cleared.
The following fault types will activate the fault output:
Line fail (any module), ARC comms fail (any module), RF jam, RF low battery, RF supervision failure, Bell fail
(from a bell fail zone), AC fail (panel, AC zone or power supply), Battery fail (panel, battery zone or power
supply), Mask.
SMS signalling faults will not activate the fault outputs.