52 - Program Zones (cont'd)
06 Dual (Double Knock)
The operation of the Dual (Double Knock) function is identical to the Intruder function, with the exception
that an alarm condition is activated only when there have been two activations from any Dual zones (assigned
to the same group) within a 20 minute period while the system is set.
07 Entry
This function initiates the unsetting procedure in the same way as a Final zone. However, during the setting
routine an Entry zone operates as an Exit zone type. This function is normally used in conjunction with a
Push Set zone, which acts as the exit terminator for the setting procedure.
Pressing the
key when programming an Entry zone doubles the entry time of the group.
Opening an Entry zone during the exit time is reported on the keypad as an open zone; the Entry/Exit
Horns bleep rapidly to indicate that the zone is open.
08 Push Set
This zone function is used to terminate the setting routine. The system sets when the Push Set zone, usually a
push button, is activated. The Entry/Exit Horn stops immediately the button is pressed; the system sets after
four seconds, allowing the doors to settle to the closed state. The Push Set zone remains inactive until the
next setting routine.
NOTE: The Push Set zone can be either 1kΩ going to 2kΩ or 2kΩ to 1kΩ - refer to Installation Manual
(II1-0033), System Architecture for wiring details. The first time that the Push Set is used to
terminate the setting, the button will require to be pressed twice; the first press identifies the normal
status of the button to the system.
Activating a Push Set zone during the exit time is not reported on the keypad as an open zone; the Entry/
Exit Horns bleep rapidly to indicate that the zone is open.
NOTE: The termination feature of a Final zone can be extended to terminate the setting of multiple groups
by pressing the
09 Keyswitch
The Keyswitch function allows a zone to be used as an on/off switch for the system or assigned groups.
Operating a Keyswitch zone when the system is unset starts the timed full setting routine, therefore the exit
time is applicable. The system sets when the exit time expires or a Final or Push Set is activated.
NOTE: Assigning a # to the keyswitch zone function will cause the Instant setting routine to be activated. In
this case the exit time is not applicable. If a Keyswitch Zone has its omit attribute enabled, activation
of the Keyswitch will force set the assigned groups. Only zones with the omit attribute enabled will
be omitted.
When the keyswitch is activated twice during the exit time of an autoset, the autoset is temporarily cancelled
for a few seconds, then it restarts the exit time causing the panel to reset.
Operating a keyswitch zone type during the pre-warn period of an autoset will start a Force Set. If you then
activate the switch again (i.e. unset with keyswitch) before the panel sets, the pre-warn continues on the
autoset.
NOTE: When the keyswitch is activated the second time to take panel back into pre-warn, it can be up to
10 seconds before the pre-warn tones at the keypad start up again.
key when assigning a group to the zone. Refer to the Star