45 - Timer Control (cont'd)
Use the A or B key to move between the different holiday periods or enter the number of the holiday period
(1 – 10) to be programmed.
The holiday periods can only be programmed by the master manager and engineer. Users can access this
option, however, they can only view the programmed holiday dates.
2 = Assign Groups
This function determines which of the groups are affected by the programmed holiday periods.
On selecting the Assign Groups option, the groups currently assigned to the programmed holiday periods are
indicated by a Y below the group; an N is displayed below the unassigned groups. All groups default to Y.
Pressing the group number toggles the group status. When the required groups have been assigned to the
holidays, press the ent key to accept the programming and return to the previous menu level.
Multi-group Systems
The larger Galaxy panels have 32 groups; these are displayed on the keypad in blocks of eight groups, sub-
divided into A, B, C and D:
Press keys 1 – 8 to assign the relevant groups in each block to the user.
45.3 = Early Open
If the Early Open option (45.3.2) is enabled, the Lockout OFF time (refer to option 65 = TIMERS) for
the following day is brought forward by the number of minutes (0 – 240) programmed in parameter 44 =
Early Open. This allows the system to be manually unset earlier than normal.
1 = Early Times
If the Timer is set to off, the operation of the Timer is suspended; this option cannot be used to alter the
programmed times. The timer defaults to 0 = Off. To switch the timer on, select change the setting to 1 =On.
The Timer Status can also be altered through menu option 65.1 by the engineer only.
On selecting the option, the early opening status of the groups is displayed; early opening enabled is indicated
by a Y below the group; an N is displayed below the groups that are not programmed to open early. All
groups default to N.
NOTE: Only the engineer can enable early opening for individual groups, but global enable must be done
first.
2 = Early Open
Type 3. 6 Users and Engineer when Groups are Disabled
If groups have not been enabled on the system, the programming of the Early Open option is identical for
type 3.6 users and the engineer; the option permits early opening to be disabled or enabled:
0
=
Disabled (default) — early opening not permitted;
1
=
Enabled — early opening permitted.
Select the required status and press the ent key to accept the programming and return to the previous menu.
Engineer Mode with Groups Enabled
If groups have been enabled (option 63 = OPTIONS + early open permitted), then the groups can be
individually enabled to permit early opening.