Option 23 - System - Honeywell Galaxy Dimension Series Installer Manual

Hide thumbs Also See for Galaxy Dimension Series:
Table of Contents

Advertisement

Galaxy Dimension Installer Manual
K = Keypad
AB Line
NOTES:
1.
Where two identical events occur within 1 second, only one is logged.
2.
Only the first occurrences of high resistance and low resistance events on each day are logged.
Subsequent activations are ignored until midnight of the same day. This is to prevent the log
from being filled with high and low resistance activations from a faulty zone.
The event log can be printed while accessing the Display Log option. Pressing the
event starts the printout from the displayed event and prints forward to the most recent event. The esc key
aborts the print out.
NOTE: A serial printer must be connected to the Galaxy panel via a printer interface module, the RS232
interface module, or the RS232 serial port.
Option 23 – System
This option provides a quick overview of the system configuration; two lines of information are displayed at a
time - the A and B keys are used to scroll through the entire list:
Groups
Group status
NOTE: Enabling the Show Status option (refer to option 58 = KEYPADS) allows the group set status to
be displayed from the normal banner (when the system is set or unset) by pressing the
simultaneously.
Type
Version
RIOs fitted
Codes used
Keypads fitted
Comms modules 1-7 (Telecom, RS232, ISDN, Ethernet, Int Telecom, Int RS232, Audio Module);
Printer
MAX Modules
DCM Modules
MUX Modules
Panel location
Default Set
10:24 SUN 01 JAN
10:24 SUN 01 JAN
10:24 SUN 01 JAN
10:24 SUN 01 JAN
10:24 SUN 01 JAN
K10
K10
K10
K10
K10
use the A and B keys to scroll through groups A1–8, B1–8, C1–8 and D1–8
U = Unset, S = Set, P = Part set and L = Locked-out for each of the groups
displayed;
Galaxy 48, 96, 264 or 520;
version of software in Galaxy panel;
includes the on-board RIOs;
includes the manager, engineer and remote codes;
1–8 (Galaxy 48), 1–16 (Galaxy 96/264), 1–32 (Galaxy 520);
0–1 (Printer Interface Module);
gives the number of MAX modules on the system;
gives the number of Door Control Modules on the system;
gives the number of MUX Modules on the system
up to 16 characters of text entered in System Text parameter (option 51.15.2).
gives the default settings set up in menu 51.17.
L7
L7
L7
L7
L7
Level of User Code
Keypad Address
6-17
23 - System
key while displaying an
and # keys

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents