Event Log (cont'd)
KEYPAD TEXT
LOC WRITE
Diagnostics local write event
+LOCKTIMER
Lockout timer activated.
–LOCKTIMER
Lockout timer de-activated.
+LOG
Log zone activated (opened).
–LOG
Log zone de-activated (closed).
LOG 90%
Event log 90% full
LOG DELAY
Log Delay zone has been activated (opened) for longer than the Delay Alarm time.
+LOW RES
Zone changing to low resistance (900 to 800 Ohm).
–LOW RES
Zone changing from Low Resistance to Normal Closed (800 to 900 Ohm).
+LOW VOLTS
Voltage of AUX outputs has dropped below 10V.
+MASK
Mask zone activated (opened).
–MASK
Mask zone de-activated (closed).
MASKED
Zone masked. Detector has activated its masking output.
MAX ALARM
MAX alarm — door forced.
MAX TAMP
MAX Tamper
MEM RESET
Memory Reset (Restart) to factory default settings (Cold Start).
+MISSING
Module Missing its AB (RS485) communications.
–MISSING
Module that was Missing now has its AB (RS485) communications re-established.
MOD CODES
Modify Codes menu (Menu Option 42) has been accessed.
MOD REM
Remote Servicing menu (Menu Option 47) has been accessed.
MOD SUMMR
Modify Summer menu (Menu Option 43) has been accessed.
MOD T/D
Modify Time/Date menu (Menu Option 42) has been accessed.
MOD TMRS
Modify Timers Control menu (Menu Option 45) has been accessed.
NEW T/D
New Time/Date after modification.
OMIT ATM1
Omit all ATM1 zones.
OMIT ATM2
Omit all ATM2 zones.
OMIT ATM3
Omit all ATM3 zones.
OMIT ATM4
Omit all ATM4 zones.
OMIT VIBS
Mass omit of vibration zones.
OMIT ZONE
Omit zones menu (menu option 0 in Quick Menu or menu option 11 in Full Menu has been
accessed.
OMITTED
Zone has been omitted
OVERRIDE
Event has been overridden to set the system
OVWR SITE
Remote overwrite of the site has occured via Remote Servicing or RS232 module
P.AUDIBLE
PA Audible zone activated (opened).
PA
PA zone activated (opened)
NOTE:
M = Mandatory. NM = Non-Mandatory
NOTE:
A plus (+) means an event has started. A negative (-) means an event has finished.
DESCRIPTION
D-4
Galaxy Dimension Installer Manual
Trigger Event
None
None
None
16. Log
16. Log
Always TR
16. Log
15. Trouble
15. Trouble
13. Elec Status
15. Trouble
4. Security
4. Security
18. Zone restoral
15. Trouble
20. Fault
4. Security
17. Max Tag
9. Tamper
13. Elec Status
9. Tamper
9. Tamper
18. Zone restoral
14. Menu Access
14. Menu Access
14. Menu Access
14. Menu Access
14. Menu Access
Always TR
8. Omit
8. Omit
8. Omit
8. Omit
8. Omit
None
8. Omit
None
None
None
1. PA/Duress
M
NM
NM
NM
NM
NM
NM
M
M
M
M
M
M
M
M
NM
M
M
M
NM
NM
M
NM
M
M
M
M
M
M
M
M
M
M
NM
M