Figure 8-106 Display Dhp Trace Cp Side Window - Hitachi S10VE User Manual

Table of Contents

Advertisement

8. Tools
(6) The Display DHP trace window appears.
When displaying DHP trace information for the HP side, the window title is Display DHP trace HP side.
When displaying DHP trace information for the ET.NET module (main or sub), the window title is
Display DHP trace ET.NET(Main/Sub).
The following table lists the DHP trace information displayed in this window.
DHP
TIME
EVENT
TN
LV
DATA1 to DATA5
(5) To display the latest DHP trace information, click Refresh.
(6) To save the displayed DHP trace information to a text file, click Save.
(7) Click Close to close the Display DHP trace window (Figure 8-106).
(8) Click Close to close the DHP Information window (Figure 8-105).

Figure 8-106 Display DHP trace CP side window

Item
The DHP trace display number.
The time at which the trace was recorded.
tt.tttttt
Second Time output to one microsecond
The trace point type.
The task number.
The priority level.
The trace data (in hexadecimal format).
Displayed information
8-96