Check the wire harness for open or short circuits.
Install a new Main PWB,
PL 1.1 Item
Check the voltage to the Over Heat Thermostat. The voltage is present.
Y
N
Verify the input AC line voltage to the LVPS PWB is correct, refer to,
Check the Over Heat Thermostat for contamination.
Check the wire harness for open or short circuits.
Install a new:
1.
LVPS,
PL 4.1 Item
3.
2.
HVPS,
PL 4.1 Item
2.
If the fault persists, install a new Fuser Module,
Status Indicator RAPs
10-100 , 10-200, 10-300
4.
BSD
1.
PL 5.1 Item
26.
10-200, 10-300 Fuser Temperature Error RAP
BSD-ON:BSD 1
Control Panel Fault Displayed
10-200 The temperature of the Fuser did not reach normal operating range of 383°F ± 5°F
(195°C ± 5°C).
B205: Low Heat error
B215: Fuser Error
10-300 The temperature of the Fuser exceeds normal operating range of 383°F ± 5°F (195°C ±
5°C).
B205: Over Heat error
B215: Fuser Error
Do not perform repair activities with the power on or electrical power supplied to the
machine. The machine could activate and cause serious personal injury when the power
is on or electrical power is supplied.
DANGER: Ne pas effectuer de dépannage avec le contact principal activé ou avec l'ali-
mentation électrique appliquée à la machine: celle-ci pourrait démarrer et causer de
graves blessures.
AVVERTENZA: Non effettuare alcuna riparazione con la macchina accesa o con l'ali-
mentazione elettrica inserita. La macchina potrebbe avviarsi all'improvviso e causare
gravi ferite.
VORSICHT: Es dürfen keine Reparaturarbeiten durchgeführt werden, solange das Gerät
eingeschalten oder mit der Stromquelle verbunden ist. Das Gerät kann u.U in den Aktiv-
Zustand übergehen und somit erhebliche körperliche Schäden verursachen.
AVISO: No realice reparaciones con la máquina encendida o conectada a la corriente.
La máquina podría activarse y ocasionar daños personales graves.
Procedure
Enter Diagnostic Mode,
GP
1, [DC330, [109] Fuser Temperature A] to obtain a temperature
reading from the Fuser. The Fuser temperature is within normal operating range.
Y
N
Install a new Fuser Module,
If problem is intermittent, check the Fuser Module connector is not cracked, broken, or other
damage. Repair or replace as required.
July 2019
2-20
WARNING
PL 5.1 Item
26.
Xerox® B205/B215 Multifunction Printer Service Manual