Xerox B205 Service Manual page 36

Hide thumbs Also See for B205:
Table of Contents

Advertisement

08-600 Paper Jam in Duplex Area RAP
BSD-ON:BSD 1
Control Panel Fault Displayed
B205: Jam at duplex path
B215: Jam in the Device
The machine has detected a paper jam in the Duplex Area.
Initial Actions
Remove jammed sheets from duplex area. Refer to Section 11 in the Xerox® B215/B205 User
Guide for detailed instructions on clearing paper jams.
Ensure that the paper guide and machine settings are correct for the paper that is loaded in the
tray.
Procedure
Check the Exit Sensor Actuator. The actuator moves freely.
Y
N
Install a new Exit Sensor Actuator.
Enter Diagnostic Mode,
GP
1, [DC330, [102] Out-Bin Full Sensor] to block and clear the Exit
Sensor. The sensor is OK.
Y
N
1.
Check that there is no contamination present.
2.
Check for an open or short circuit.
3.
Install a new Exit Sensor,
PL 4.1 Item
Check the following parts for wear or damage and replace if needed:
Duplex Paper Guide,
PL 4.2 Item
6.
Duplex Gate,
PL 2.1 Item
7.
Duplex Gate Spring,
PL 2.1 Item
8.
Exit Paper Guide,
PL 2.1 Item
6.
Verify the Duplex Gate is seated correctly and moves freely without binding.
Initial Release
Xerox® B205/B215 Multifunction Printer Service Manual
24.
08-700 Output Bin Full Fault
BSD-ON:
BSD 1
Control Panel Fault Displayed
B205: Output Bin Full. Remove Paper
B215: Output Bin Full. Remove Paper
The Output Tray Full Sensor has detected that the Output Tray is full.
Initial Actions
Remove sheets from the Output Tray. (Maximum capacity is 150 sheets/ standard paper 8.5 x
11 in./ 80g/m2.)
Procedure
Enter Diagnostics Mode. Select: [Machine Test, EDC Mode, DC330 Component Control,
102-Sensor, Out Bin Full] to test the Out Bin Full Sensor. The signal changes.
Y
N
Check the sensor connector is fully seated.
Check for and remove any contamination present.
Check for an open or short circuit.
Install a new Output Tray Full Sensor,
Check the Bin Full Sensor Actuator,
to respond intermittently or fail to actuate the Output Tray Full Sensor. Clean the Bin Full Sen-
sor Actuator and surrounding area to full operation.
July 2019
2-15
PL 4.3 Item
1.
PL 2.2 Item
7, for binding or any debri causing the actuator
Status Indicator RAPs
08-600 , 08-700

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B215

Table of Contents