Xerox B205 Service Manual page 123

Hide thumbs Also See for B205:
Table of Contents

Advertisement

3.
Disconnect the Fuser Connectors (2),
a.
Connector CON 2 from the LVPS PWB.
b.
Connector FUSER from the Main PWB.
Figure 1 Fuser Connectors
NOTE: Remember the location of the Screw with the larger head for Fuser replacement.
Repairs / Adjustments
REP 5.1
Figure
1.
CON2
FUSER
4.
Remove the Fuser Module screws (4),
Remove the Fuser, routing the wires through the frame opening.
Figure 2 Fuser Screws (Rear View)
Replacement
NOTE: Tapered Plastic Screws and Round Machine Screws are used to hold the Fuser to the
frame. Make sure that the Plastic Screws go into plastic components and Machine Screws go
into the metal frame.
Install the components in the reverse of removal.
July 2019
4-56
Figure
2.
Screws