Check the Flat Cable for excessive wear, breaks in the insulation cover, and no
contamination present.
Disconnect and securely reconnect the Flat Cable.
Check the Flat Cable for an open or short circuit. The Flat Cable is good.
Y
N
Install a new Flat Cable,
PL 4.1 Item
Install a new Laser Scanner Unit (LSU),
Go to SCP 04 Final Actions.
Initial Release
Xerox® B205/B215 Multifunction Printer Service Manual
1.
PL 4.1 Item
22.
07-110 Paper Tray 1 Empty RAP
BSD-ON:BSD 1
Control Panel Fault Displayed
B205: Tray 1 Empty
B215: Tray 1 is Out of Paper
The Exit Sensor failed to detect paper in the tray.
Initial Actions
Ensure that paper is loaded in the tray. Clear any jammed sheets. Refer to Section 11 in the
WorkCentre B215/B205 User Guide for detailed instructions on clearing paper jams.
Do not perform repair activities with the power on or electrical power supplied to the
machine. The machine could activate and cause serious personal injury when the power
is on or electrical power is supplied.
DANGER: Ne pas effectuer de dépannage avec le contact principal activé ou avec l'ali-
mentation électrique appliquée à la machine: celle-ci pourrait démarrer et causer de
graves blessures.
AVVERTENZA: Non effettuare alcuna riparazione con la macchina accesa o con l'ali-
mentazione elettrica inserita. La macchina potrebbe avviarsi all'improvviso e causare
gravi ferite.
VORSICHT: Es dürfen keine Reparaturarbeiten durchgeführt werden, solange das Gerät
eingeschalten oder mit der Stromquelle verbunden ist. Das Gerät kann u.U in den Aktiv-
Zustand übergehen und somit erhebliche körperliche Schäden verursachen.
AVISO: No realice reparaciones con la máquina encendida o conectada a la corriente.
La máquina podría activarse y ocasionar daños personales graves.
Procedure
Check the Exit Sensor Actuator,
PL 4.5 Item
aged.
Y
N
Install a new Exit Sensor Actuator,
Enter Diagnostic Mode,
GP
1, [DC330, [102], Tray 1 Empty] to block and clear the Tray 1
Empty Sensor. The sensor signal changes.
Y
N
Check for 3.3VDC on the Main PWB. The voltage is present on the Main PWB.
Y
N
Check that all voltages are present between the HVPS PWB and the Main PWB.
The voltages between the HVPS PWB and the Main PWB are present
Y
N
Install a new HVPS PWB,
Install a new Main PWB,
Install a new Exit Sensor,
A
B
July 2019
2-9
WARNING
5. The actuator moves freely and is undam-
PL 4.5 Item
5.
PL 4.1 Item
2.
PL 1.1 Item
4.
PL 4.5 Item
3.
Status Indicator RAPs
06-100 / 200 , 07-110

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B215

Table of Contents