Connector Module
2M
The S
connector module allows you to operate an OpenCom 130 / 150 on a primary
2M
rate access. This access provides up to 30 voice channels. You can also use the S
port to network two systems, e.g. in order to use the OpenCom 130 / 150 as a sub-
sidiary system or DECT server.
Note on DECT Applications in Conjunction with S
If an S
connector module is installed in the OpenCom 130 / 150, please consider the
2M
following restriction for DECT applications:
It is not sufficient, to install a U
with the OpenCom 150). In every case, you need to run a U
"8 x U
" or "2 x S
and 6 x U
pn
0
properly.
Note
The maximum cable attenuation between the OpenCom 130 / 150 and the other
system (NT or telephone exchange) must not exceed 6 dB. This corresponds to a
length of approx. 150 to 200 m, depending on the type of cable used.