Aastra OpenCom 100 Series Mounting And Commissioning User Manual page 43

Hide thumbs Also See for OpenCom 100 Series:
Table of Contents

Advertisement

1.
Open the Telephony: Trunks: Route menu.
On the status page, the list of previously configured routes is displayed.
2.
Click on the New button. Alternatively, click one of the route entries to assign the
bundle to an existing route.
3.
Select the bundle you have configured from the Choice list and enter a route
name in the Name field (only if you are configuring a new route).
4.
Click on the Apply button.
The newly configured or changed route is displayed in the list on the status page.
Configuring the a/b ports
In the following step, you have to configure each of the M100-AT4 Interface Card
ports:
1.
Open the Telephony: Ports: a/b menu.
The four M100-AT4 Interface Card ports are displayed for the selected slot.
2.
Click on the desired a/b port.
3.
Select the configured bundle from the Bundle list. Enter the desired access
number in the Port Ph. No. field.
4.
Click on the Apply button.
Configuring the call distribution
In order to allow incoming calls to be signalled to the designated terminals, the access
numbers configured for the M100-AT4 Interface Card a/b ports must be assigned to
internal call numbers:
1.
Open the Telephony: Call Distribution: Incoming menu.
Previously assigned access numbers are displayed in the list. The list also displays
the access numbers of the a/b ports you have configured.
2.
In the Phone no. column, click the entry you wish to assign internal call numbers
to.
3.
Enter up to ten internal call numbers to which incoming external calls are to be
signalled.
4.
Click on the Apply button.
5.
Repeat steps 2 to 4 until all allocations have been set in the call distribution.
Installation
41