Technical Specifications
OpenCom 150 (Cont.)
– Supply power
– Range
a/b ports
for analogue terminals with pulse or
DTMF dialling, flash duration of 60 to
310 ms
– Supply voltage
– Supply power
– Feed current
– Range
V.24 port (COM)
for connection of a PC
– Range
Doorstation equipment interface card
for connection of doorstation equip-
ment
Contact load of actor
– Voltage range
Sensor
– Voltage range
Note
The online help provides an overview of the limits that should be observed when
configuring the OpenCom 100.
244
3 VA per U
bus
pn
1,000 m
Possible interface cards:
– 4 x a/b
– 8 x a/b
– 2 x S
and 6 x a/b
0
40 V ± 10%
1.2 VA
25 mA
1,000 m
1 x (optional)
3 m
1 x (optional)
1.5 A / 125 V
U
= 5 V...30 V
≈
Switched by low AC voltage
U
= 6 V...24 V
~