Drive
Continuous (3x380–440 V) [A]
Intermittent (3x380–440 V) [A]
Continuous (3x441–480 V) [A]
Intermittent (3x441–480 V) [A]
Maximum mains fuses
Estimated power loss [W], best
case/typical
(1)
Weight enclosure protection
rating IP20 [kg (lb)]
Efficiency [%], best case/typical
(2)
Output current - 50°C (122°F) ambient temperature
Continuous (3x380–440 V) [A]
Intermittent (3x380–440 V) [A]
Continuous (3x441–480 V) [A]
Intermittent (3x441–480 V) [A]
1
Applies for dimensioning of drive cooling. If the switching frequency is higher than the default setting, the power losses may increase. LCP and typical control card power consump-
tions are included. For power loss data according to EN 50598-2, refer to Danfoss
2
Typical: under rated condition. Best case: the optimal condition is adopt, such as the higher input voltage and lower switching frequency.
Table 23: 3x380–480 V AC, 18.5–90 kW (25–125 hp), Enclosure Sizes H5–H8
Drive
Typical shaft output [kW]
Typical shaft output [hp]
Protection rating IP20
Maximum cable size in termi-
2
nals (mains, motor) [mm
(AWG)]
Output current-40°C (104°F) ambient temperature
Continuous (3x380–440 V)[A]
Intermittent (3x380–440 V) [A]
Continuous (3x441–480 V) [A]
Intermittent (3x441–480 V) [A]
Maximum input current
Continuous (3x380–440 V) [A]
Intermittent (3x380–440 V) [A]
Continuous (3x441–480 V) [A]
68 | Danfoss A/S © 2019.11
PK37
PK75
P1K5
1.2
2.1
3.5
1.3
2.3
3.9
1.0
1.8
2.9
1.1
2.0
3.2
See
3.2.4.5 Recommendation of Fuses and Circuit
13/15
16/21
46/57
2.0
2.0
2.1
(4.4)
(4.4)
(4.6)
97.8/9
98.0/9
97.7/9
7.3
7.6
7.2
1.04
1.93
3.7
1.1
2.1
4.07
1.0
1.8
3.4
1.1
2.0
3.7
MyDrive® ecoSmart
P18K
P22K
P30K
18.5
22.0
30.0
25.0
30.0
40.0
H5
H5
H6
16 (6)
16 (6)
35 (2)
37.0
42.5
61.0
40.7
46.8
67.1
34.0
40.0
52.0
37.4
44.0
57.2
35.2
41.5
57.0
38.7
45.7
62.7
29.3
34.6
49.2
P2K2
P3K0
P4K0
4.7
6.3
8.3
5.2
6.9
9.1
3.9
5.3
6.8
4.3
5.8
7.5
46/58
66/83
95/11
8
3.3
3.3
3.4
(7.3)
(7.3)
(7.5)
98.3/9
98.2/9
98.0/9
7.9
7.8
7.6
4.85
6.3
8.4
5.4
6.9
9.2
4.4
5.5
7.5
4.8
6.1
8.3
TM
website.
P37K
P45K
37.0
45.0
50.0
60.0
H6
H6
35 (2)
35 (2)
73.0
90.0
80.3
99.0
65.0
80.0
71.5
88.0
70.0
84.0
77.0
92.4
60.6
72.5
Specifications
P5K5
P7K5
P11K
11.2
15.1
22.1
12.3
16.6
24.3
9.4
12.6
18.4
10.3
13.9
20.2
Breakers.
104/1
159/1
248/2
31
98
74
4.3
4.5
7.9
(9.5)
(9.9)
(17.4)
98.4/9
98.2/9
98.1/9
8.0
7.8
7.9
10.9
14.0
20.9
12.0
15.4
23.0
10.0
12.6
19.1
11.0
13.9
21.0
P55K
P75K
55.0
75.0
70.0
100.0
H7
H7
50 (1)
95 (0)
(250MC
106.0
147.0
116.0
161.0
105.0
130.0
115.0
143.0
103.0
140.0
113.0
154.0
88.6
120.9
AQ275641848264en-000101 / 132R0078
P15K
29.9
32.9
24.7
27.2
353/3
79
7.9
(17.4)
98.0/9
7.8
28.0
30.8
24.0
26.4
P90K
90.0
125.0
H8
120
M)
177.0
194.0
160.0
176.0
166.0
182.0
142.7