Danfoss VLT HVAC Basic Drive FC 101 Operating Manual page 78

Hide thumbs Also See for VLT HVAC Basic Drive FC 101:
Table of Contents

Advertisement

Operating Guide | VLT® HVAC Basic Drive FC 101
Programmable relay outputs
Relay 01 terminal number (enclosure size H9)
Maximum terminal load (AC-1)
Maximum terminal load (AC-15)
Maximum terminal load (DC-1)
Maximum terminal load (DC-13)
Relay 01 and 02 terminal number (enclosure size H6, H7, H8, H9 (relay 2 only), H10, and
I6–I8)
Maximum terminal load (AC-1)
Maximum terminal load (AC-15)
Maximum terminal load (DC-1)
Maximum terminal load (DC-13)
Maximum terminal load (AC-1)
Maximum terminal load (AC-15)
Maximum terminal load (DC-1)
Maximum terminal load (DC-13)
Minimum terminal load on 01–03 (NC), 01–02 (NO), 04–06 (NC), 04–05 (NO)
Environment according to EN 60664-1
1
IEC 60947 parts 4 and 5. Endurance of the relay varies with different load type, switching current, ambient temperature, driving configuration, working profile, and so forth. It is
recommended to mount a snubber circuit when connecting inductive loads to the relays.
2
Overvoltage Category II.
3
UL applications 300 V AC 2 A.
6.4.12 Control Card, 10 V DC Output
Terminal number
Output voltage
Maximum load
6.4.13 Ambient Conditions
Enclosure protection rating
Enclosure kit available
Vibration test
Maximum relative humidity
Aggressive environment (IEC 60721-3-3), coated (standard) enclosure
sizes H1–H5
Aggressive environment (IEC 60721-3-3), non-coated enclosure sizes
H6–H10
Aggressive environment (IEC 60721-3-3), coated (optional) enclosure
sizes H6–H10
78 | Danfoss A/S © 2019.11
(1)
on 01–03 (NC), 01–02 (NO) (resistive load)
(1)
(inductive load @ cosφ 0.4)
(1)
on 01–02 (NO), 01–03 (NC) (resistive load)
(1)
(inductive load)
(1)
on 04–05 (NO) (resistive load)
(1)
on 04–05 (NO) (inductive load @ cosφ 0.4)
(1)
on 04–05 (NO) (resistive load)
(1)
on 04–05 (NO) (inductive load)
(1)
on 04–06 (NC) (resistive load)
(1)
on 04–06 (NC) (inductive load @ cosφ 0.4)
(1)
on 04–06 (NC) (resistive load)
(1)
on 04–06 (NC) (inductive load)
(2) (3)
5–95% (IEC 60721-3-3; Class 3K3 (non-condensing)) during
Specifications
01–03 (NC), 01–02 (NO)
01–03 (NC), 01–02 (NO), 04–06 (NC), 04– 05
24 V DC 10 mA, 24 V AC 20 mA
Overvoltage category III/pollution degree 2
IP20, IP54 (not for outdoor installation)
AQ275641848264en-000101 / 132R0078
240 V AC, 2 A
240 V AC, 0.2 A
60 V DC, 1 A
24 V DC, 0.1 A
(NO)
400 V AC, 2 A
240 V AC, 0.2 A
80 V DC, 2 A
24 V DC, 0.1 A
240 V AC, 2 A
240 V AC, 0.2 A
50 V DC, 2 A
24 V DC, 0.1 A
50
10.5 V ±0.5 V
25 mA
IP21, TYPE 1
1.0 g
operation
Class 3C3
Class 3C2
Class 3C3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT HVAC Basic Drive FC 101 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents