Danfoss VLT HVAC Basic Drive FC 101 Operating Manual page 72

Hide thumbs Also See for VLT HVAC Basic Drive FC 101:
Table of Contents

Advertisement

Operating Guide | VLT® HVAC Basic Drive FC 101
Drive
Continuous (3x551–600 V) [A]
Intermittent (3x551–600 V) [A]
1
Applies for dimensioning of drive cooling. If the switching frequency is higher than the default setting, the power losses may increase. LCP and typical control card power consump-
tions are included. For power loss data according to EN 50598-2, refer to Danfoss
2
Efficiency measured at nominal current. For energy efficiency class, see
Table 27: 3x525–600 V AC, 18.5–90 kW (25–125 hp), Enclosure Sizes H6–H8
Drive
Typical shaft output [kW]
Typical shaft output [hp]
Protection rating IP20
Maximum cable size in termi-
2
nals (mains, motor) [mm
(AWG)]
Output current - 40°C (104°F) ambient temperature
Continuous (3x525–550 V) [A]
Intermittent (3x525–550 V) [A]
Continuous (3x551–600 V) [A]
Intermittent (3x551–600 V) [A]
Maximum input current
Continuous (3x525–550 V) [A]
Intermittent (3x525–550 V) [A]
Continuous (3x551–600 V) [A]
Intermittent (3x551–600 V) [A]
Maximum mains fuses
Estimated power loss [W], best
(1)
case/typical
Weight enclosure protection
rating IP54 [kg (lb)]
Efficiency [%], best case/typical
(2)
Output current - 50°C (122°F) ambient temperature
Continuous (3x525–550 V) [A]
Intermittent (3x525–550 V) [A]
Continuous (3x551–600 V) [A]
Intermittent (3x551–600 V) [A]
72 | Danfoss A/S © 2019.11
P2K2
P3K0
2.7
3.4
3.0
3.7
MyDrive® ecoSmart
6.4.13 Ambient Conditions
P18K
P22K
P30K
18.5
22.0
30.0
25.0
30.0
40.0
H6
H6
35 (2)
35 (2)
35 (2)
28.0
36.0
43.0
30.8
39.6
47.3
27.0
34.0
41.0
29.7
37.4
45.1
27.0
33.1
45.1
29.7
36.4
49.6
25.7
31.5
42.9
28.3
34.6
47.2
See
3.2.4.5 Recommendation of Fuses and Circuit
385
458
542
24.5 (54)
24.5 (54)
24.5 (54)
98.4
98.4
98.5
19.6
25.2
30.1
21.6
27.7
33.1
18.9
23.8
28.7
20.8
26.2
31.6
P3K7
P5K5
4.3
6.3
4.7
6.9
TM
website.
. For part load losses, see Danfoss
P37K
P45K
37
45.0
50.0
60.0
H6
H7
H7
50 (1)
50 (1)
54.0
65.0
59.4
71.5
52.0
62.0
57.2
68.2
54.7
66.5
60.1
73.1
52.0
63.3
57.2
69.6
597
727
36.0
36.0
(79.3)
(79.3)
98.5
98.7
37.8
45.5
41.6
50.0
36.4
43.3
40.0
47.7
Specifications
P7K5
P11K
7.7
12.6
8.5
13.9
TM
MyDrive® ecoSmart
website.
P55K
P75K
55.0
75.0
70.0
100.0
H7
H8
50 (1)
95 (0)
120 (4/0)
87.0
105.0
95.7
115.5
83.0
100.0
91.3
110.0
81.3
109.0
89.4
119.9
77.4
103.8
85.1
114.2
Breakers.
1092
1380
36.0
51.0
(79.3)
(112.4)
(112.4)
98.5
98.5
60.9
73.5
67.0
80.9
58.1
70.0
63.9
77.0
AQ275641848264en-000101 / 132R0078
P15K
15.4
16.9
P90K
90.0
125.0
H8
137.0
150.7
131.0
144.1
130.9
143.9
124.5
137.0
1658
51.0
98.5
95.9
105.5
91.7
100.9

Advertisement