3X380-480 V Ac - Danfoss VLT HVAC Basic Drive FC 101 Operating Manual

Hide thumbs Also See for VLT HVAC Basic Drive FC 101:
Table of Contents

Advertisement

Operating Guide | VLT® HVAC Basic Drive FC 101
Drive
Maximum cable size in terminals
2
(mains, motor) [m
(AWG)]
Output current - 40°C (104°F) ambient temperature
Continuous (3x200–240 V) [A]
Intermittent (3x200–240 V) [A]
Maximum input current
Continuous 3x200–240 V) [A]
Intermittent (3x200–240V) [A]
Maximum mains fuses
Estimated power loss [W], Best
(1)
case/typical
Weight enclosure protection rat-
ing IP20 [kg (lb)]
Efficiency [%], best case/typical
Output current - 50°C (122°F) ambient temperature
Continuous (3x200–240 V) [A]
Intermittent (3x200–240 V) [A]
1
Applies for dimensioning of drive cooling. If the switching frequency is higher than the default setting, the power losses may increase. LCP and typical control card power consump-
tions are included. For power loss data according to EN 50598-2, refer to Danfoss
2
Efficiency measured at nominal current. For energy efficiency class, see
6.1.2 3x380–480 V AC
Table 22: 3x380–480 V AC, 0.37–15 kW (0.5–20 hp), Enclosure Sizes H1–H4
Drive
Typical shaft output [kW]
Typical shaft output [hp]
Protection rating IP20
Maximum cable size in terminals
2
(mains, motor) [mm
(AWG)]
Output current - 40°C (104°F) ambient temperature
Continuous (3x380–440 V)[A]
Intermittent (3x380–440 V) [A]
Continuous (3x441–480 V) [A]
Intermittent (3x441–480 V) [A]
Maximum input current
Danfoss A/S © 2019.11
P11K
P15K
16 (6)
35 (2)
42.0
59.4
46.2
65.3
41.0/38.2
52.7
45.1/42.0
58.0
See
369/386
512
9.5 (20.9)
24.5 (54)
97.2/97.1
97.0
(2)
33.0
41.6
36.3
45.8
MyDrive® ecoSmart
6.4.13 Ambient Conditions
PK37
PK75
P1K5
0.37
0.75
1.5
0.5
1.0
2.0
H1
H1
H1
4 (10)
4 (10)
4 (10)
1.2
2.2
3.7
1.3
2.4
4.1
1.1
2.1
3.4
1.2
2.3
3.7
P18K
P22K
35 (2)
50 (1)
74.8
88.0
82.3
96.8
65.0
76.0
71.5
83.7
3.2.4.5 Recommendation of Fuses and Circuit
697
879
24.5 (54)
36.0 (79.4)
97.1
96.8
52.4
61.6
57.6
67.8
TM
website.
. For part load losses, see Danfoss
P2K2
P3K0
P4K0
2.2
3.0
3.0
4.0
H2
H2
4 (10)
4 (10)
4 (10)
5.3
7.2
5.8
7.9
4.8
6.3
5.3
6.9
P30K
P37K
50 (1)
95 (0)
115.0
143.0
126.5
157.3
103.7
127.9
114.1
140.7
Breakers.
1149
1390
36.0 (79.4)
51.0
(112.4)
97.1
97.1
80.5
100.1
88.6
110.1
MyDrive® ecoSmart
P5K5
P7K5
4.0
5.5
7.5
5.0
7.5
10.0
H2
H3
H3
4 (10)
4 (10)
9.0
12.0
15.5
9.9
13.2
17.1
8.2
11.0
14.0
9.0
12.1
15.4
AQ275641848264en-000101 / 132R0078| 67
Specifications
P45K
120 (4/0)
170.0
187.0
153.0
168.3
1500
51.0
(112.4)
97.3
119
130.9
TM
website.
P11K
P15K
11.0
15.0
15.0
20.0
H4
H4
16 (6)
16 (6)
23.0
31.0
25.3
34.0
21.0
27.0
23.1
29.7

Advertisement

Table of Contents
loading

Table of Contents