RSSHEUM0003 - 0101
Rev.1.00
Notes:
1, Water level sensor input port
2, UART2 interface (use +5V logical level)
3, UART1 interface (use +5V logical level)
4, Renesas emulator E8 interface
5, AD interface (use AN1 port)
6, AD interface (use AN0 port)
7, Voice module interface (reserved, also can be use as other customized function)
1.3.3 AC driving output port introduction
Below picture shows the AC driving output ports and the function simulation LEDs, which include
motor and valve AC driving output, for detail, please refer to the Notes.
1
2
Notes:
1, AC driving output port (including CW, Drain, and Inlet output)
2, AC driving output port (including CCW, Softener, and Break output)
3, Renesas Triac array (BCR8PM-14LE, BCR2PM-14LE, BCR08AM-14A)
4, Function simulation LED (simulate the AC driving output functions)
Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch
Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China
Tel: (86-21) 6888-0556
3
Fax: (86-21) 6888-0559
4
Page 15