[5]
SCANNER UTILITY
Sets the scanner unit and checks its operation.
I Function
G INITIALIZE: Initializes the scanner.
G POLYGON: Checks the operation of the polygon.
G LASER: Checks the operation of the laser.
G SAVE INITIAL LDIF: Shall not be used because it is intended for design analysis
purposes.
G HV STATUS: Displays the status of the HV switch.
G HV ON/OFF: Turns ON and OFF the HV switch (software switch).
G HV DATA: Checks the HV voltage command value that is outputted from the SCN12A
board.
G FORMAT: Fine-tunes the read start position (PIXEL) and read width (FREQ).
G SHADING/SENSITIVITY: Makes shading and sensitivity corrections.
G DATA MANAGEMENT: Saves the scanner data into the FTP server (CL) and loads the
saved scanner data.
G DIAGNOSTIC: Starts the polygon and runs a self-diagnostic check on the scanner.
G VIRTUAL IMAGE: Causes the light-collecting section to generate image data.
010-051-05
02.20.2002 FM3328
CR-IR346RU Service Manual
MU - 112
MU - 112