10-2-3 Checking the Displays

7-segment LED Display
The following figure shows the 7-segment LED display located on the front panel.
When the power is turned ON, it shows the node address that is set by the ID switches. Then the
display changes according to the setting of the LED Display Selection (4210-01 hex).
An error code is displayed if an error occurs. A warning code is displayed if a warning occurs.
● LED Display Selection (4210-01 hex) set to 0
Main circuit power ON
● LED Display Selection (4210-01 hex) set to a value other than 0
Main circuit power ON
1S-series with Built-in EtherCAT Communications and Safety Functionality User's Manual (I621)
Control circuit power ON
Main circuit power OFF
Servo ON
Servo OFF
Main circuit power OFF
Servo ON
Servo OFF
Fully OFF
Fully ON
Node address (set value of the ID switch) display (1 s)
Example: upper digit (×16) = 0 and lower digit (×1) = 3
[- -]
[- -] + Dot on right lights.
[OE] + Dot on right lights. (OE = Operation Enabled)
. The display of data that is selected in LED
Display Selection
Dot on right lights.