10 Operation
Checking the Node Address Setting
Make sure that the node address is correctly set on the ID switches.
7-segment LED display
ID switches
ID switch setting
01 to FF
Precautions for Correct Use
The ID switch setting is read only once when the Unit power supply is turned ON. Although the
setting is changed after the Unit power supply is ON, it is not reflected in the control. It is
enabled the next time the Unit power supply is turned ON.

10-2-2 Turning ON the Power Supply

Turn ON the control circuit power after you finish the checks which you must conduct before turning ON
the power supply. You can turn ON the main circuit power, but it is not a required.
10 - 4
ID
2
0
16
x
Connection to NJ/NX-series CPU Unit, NY-series IPC Machine
Controller or Position Control Unit (Model: CJ1W-NC8)
00
The controller sets the node address.
The ID switches set the node address.
1S-series with Built-in EtherCAT Communications and Safety Functionality User's Manual (I621)
CN7
0
1
x
Status indicators
Description