Connecting An External Regeneration Resistor - Omron 1 S Series User Manual

With built-in ethercat communications and safety functionality
Hide thumbs Also See for 1 S Series:
Table of Contents

Advertisement

4-4-4

Connecting an External Regeneration Resistor

Normally, short-circuit B2 and B3.
When an External Regeneration Resistor is required, remove the short-circuit wire between B2 and B3,
and connect an External Regeneration Resistor between B1 and B2 as shown below.
Servo Drive
Precautions for Correct Use
In Regeneration (4310 hex), set a value which is appropriate for the external regeneration
resistor that is connected. If you set a wrong value, the resistor may produce heat abnormally,
and fire or burning may result.
1S-series with Built-in EtherCAT Communications and Safety Functionality User's Manual (I621)
B1
External Regeneration
B2
Resistor
B3
Remove the short-circuit wire
between B2 and B3.
4 Configuration and Wiring