Fig. 36
No.: 9_6975 00 E
7
Initial Start-up
7.9
Low-temperature operation (winter)
DANGER
Fire and explosion hazard.
High currents caused by short-circuited battery. Shorted batteries can catch fire or explode.
Battery casing may crack and allow acidic fluid to spray out.
➤ Observe the instructions provided with the battery jumper cables.
➤ Do not connect the battery jumper cables to the negative pole of the discharged battery or to
the bodywork of the machine.
➤ Work with caution.
Jumper cable connection diagram
Assisting vehicle batteries
a
Machine batteries
b
Positive (+) terminal of the assisting vehicle
1
➤ Follow the safety rules when dealing with batteries:
Connect batteries of the same voltage only.
The assisting vehicle and machine to be started must not touch.
Do not bend over the batteries when attaching jumper cables.
Only use battery jumper cables of sufficient cross-sectional area and with insulated terminal
clamps.
Observe the instructions provided with the battery jumper cables.
Keep jumper cables away from rotating parts.
Do not attempt to start the machine if its batteries are frozen. Allow the batteries to thaw first.
Do not try to start the machine with a boost charger.
Connecting the battery jumper cables
1. Stop the engine of the assisting vehicle.
2. Switch off all power consumers.
3. Connect positive terminals
Service Manual
Screw Compressor
M135 SIGMA CONTROL MOBIL
Positive (+) terminal of the machine batteries
2
Bare metal point on the engine block (earth)
3
Negative (-) terminal of assisting vehicle bat‐
4
teries
and
.
2
1
71