4.11

Generator option

The ideal coolant pre-heating period is 2-3 hours before the machine is started. A pre-heating period
of more than 3 hours is not necessary, as the maximum effect has already been achieved within this
period (thermal balance).
Option ga
Generator option
A generator is installed to provide a power supply to electrical consumers. The generator is driven
from the engine by V-belts. A tensioning device automatically ensures optimum belt tension.

Operating modes

The compressor works with the normal air delivery regulation and generates electrical power at the
same time.
The generator can work in two modes. These are selected by the mode switch:
Automatic start
Continuous load
Generator main switch
OFF
ON
Generator/compressor operation
Operating mode Automatic start
Switch position Position 1
Engine speed
Electrical power takeoff > 100 VA
automatic maximum speed
Power takeoff lass than minimum:
Engine run-on time of approximately 2 minutes
at maximum speed
Advantages
Fuel saving
Constant oscillation between maximum and
minimum speed avoided
Generator operating modes

Operating controls

The switches, fuses and outlet sockets for electrical consumers are located on the generator control
box. Individual consumers are connected only by these outlet sockets.
Service Manual
Screw Compressor
M135 SIGMA CONTROL MOBIL
Mode selector switch
-
Position 1
(automatic start)
Position 2
(continuous load)
What is provided?
Compressed air
Compressed air and electrical power
Electrical power and compressed air
Continuous load
Position 2
Permanent maximum speed (en‐
gine under full load)
Continuous generator power avail‐
able without delay
51