Fig. 69 Compressor Air Filter Maintenance; Fig. 70 Cleaning The Filter Element - KAESER M135 SIGMA CONTROL MOBIL Service Manual

Screw compressor
Table of Contents

Advertisement

Material
Precondition
Fig. 69
Fig. 70
132
10
Maintenance
10.5
Compressor
Compressed air for blowing out
Spare parts (as required)
Cleaning cloths
The machine is shut down.
The machine is fully vented, the pressure gauge reads 0 bar.
Machine cooled down.
All compressed air consumers are disconnected and the air outlet valves are open.
WARNING
Damaged air filter element
Wear in the engine from intake of contaminated air.
➤ Do not try to clean the filter element by striking it.
➤ Do not wash the filter element.
Compressor air filter maintenance
Maintenance indicator
1
Red zone
2
Indicator piston
3
Reset knob for the maintenance indicator
4
Cleaning the filter element
Compressed air gun with blast pipe bent to 90° at the end
1
Filter element
2
➤ Open both doors.
Service Manual
Screw Compressor
M135 SIGMA CONTROL MOBIL
Filter element
5
Retaining clip
6
Filter cap
7
No.: 9_6975 00 E