PRINTER SPECIFICATIONS AND REQUIREMENTS

Environmental specifications

6-6
When you select a site location for your DocuPrint printer, avoid
environments with extreme variations in temperature and other
hazards, such as excessive dust or humidity. Recommended
environmental ranges for the work area are as follows:
Table 6-6.
Environmental specifications for 96/4635/180
printers
Condition
Operating
Recommended:
temperature:
Humidity: Recommended:
Altitude:
Heat dissipation:
96 and 4635
(2-stacker system)
Energy Saver:
180
(2-stacker system)
Energy Saver:
Audible noise:
XEROX DOCUPRINT 96/4635/180 IPS INSTALLATION PLANNING GUIDE
Range
68° F to 76° F /
20° C to 24° C
Minimum:
50° F / 10° C
Maximum:
85° F / 29° C
45% ±10%
Minimum:
30%
Maximum:
65%
Normal:
Up to 6,000 feet / 1,830 m
above sea level
Maximum:
9,000 feet / 2,743 m above
sea level.
Operating:
28,140 BTU/hour
Standby:
4,454 BTU/hour
2,700 BTU/hour
Operating:
32,770 BTU/hour
Standby:
4,454 BTU/hour
2,700 BTU/hour
Operating:
Continuous:
82 dB(A)
Impulse:
82 dB(A)
Standby:
Continuous:
52 dB(A)
Impulse:
N/A