11.D/A CONVERTER
11-2-1. Obtaining Current Output Signal
Use the + and - terminals of the F320 for connection with an external device
(350Ω or less load resistance).
11-2-2. Setting of D/A Zero and Gain
With the D/A converter of the F320, an analog output is obtained by setting the
indicated value to output 4mA (D/A zero set value) and the indicated value to
output 20mA (D/A full scale set value). Respective set values are inputted by the
D/A zero and full scale setting functions.
95
F320
← Inside Outside →
SIG
+
-
• The D/A converter current output is an option.
• Do not apply external currents. Breakage will result.
Also, connecting a capacity load may cause oscillation.
Current
(mA)
20
Resolution 1/10000
4
D/A zero set value
+
External device
-
Load resistance;
350Ω or less
GND
CAUTION
D/A full scale set value
Indicated value