10-3-1Equivalent Circuit - Unipulse F320 Operation Manual

Digital
Table of Contents

Advertisement

10-3-1. Equivalent Circuit
• Output
F320
Source type
Internal transistor status
Output data
0
1
+24V
A1, B1
24V
A2 ~ A12
B2 ~ B13
Out
A16, B16
0V
+24VRTN
Positive
Negative
OFF
ON
ON
OFF
Through logic switching (pin B14)
10.BCD DATA OUTPUT
PLC input unit etc.
Minus common type
In
COM
Output pin level
Output data
Positive
0
L
1
H
Negative
H
L