User Signals; User Lines Connector; Table 2-14 User Signals Connector - Xantrex ENET-XFR Operating Manual

Internal ethernet and rs-232 interface for xfr series programmable dc power supplies
Table of Contents

Advertisement

Installation and Configuration

User Signals

User Lines Connector

Table 2-14 User Signals Connector

P i n
F u n c t i o n
1
External TTL shutdown input signal (See
Polarity" on page
2
Polarity signal, open collector (asserted by VSET -x)
3
Isolation signal, open collector (asserted by OUT OFF)
4
Fault signal, open collector (asserted when bit set in fault register)
5
External Vcc, 15V maximum (supplied by connecting and
operating an external source)
6
External ground and shutdown return (supplied by connecting and
operating an external source)
7
Open collector user signal (asserted by AUXA ON)
8
Open collector user signal (asserted by AUXB ON)
2–26
Auxiliary User Lines connector, located on the
rear panel, provides several signals to increase your operating control of
the supply. These signals are dependent on the operator's design and uses.
The operation of the user lines connector signal requires that you provide
external Vcc and ground. Use a standard 8-position telephone jack and
data cable to connect to the user lines connector. To locate the connector,
refer to the
Ethernet/RS-232 Interface
page
2–5. See
Table 2-14
outputs can sink a current of 5mA each.
the portion of the option board schematic which contains the user line
connector. Use the schematic as a reference when making input or output
connections.
2–25)
subplate drawing in
for pin descriptions. The user lines connector
Figure 2-6 on page 2–27
"TTL Shutdown
Ethernet/RS-232 Interface
Figure 2-2 on
shows
User Line
Note: On some models, the
connector is rotated 180°.
TM-XR9B-01XN