Command Strings
Command Terminators
Order
TM-XR9B-01XN
If you send more than one command line, separate the commands with a
semicolon. The semicolon may be preceded or followed by spaces.
Example:
ISET 2.0A; VSET 5V
ISET 2.0A; VSET 5V
Terminators indicate the end of a command string and tell the power
supply to execute the command. The termination character is CR
(Carriage Return).
Format:
COMMAND <parameter>; COMMAND <parameter>,
<parameter><CR>
You may send commands in any order, keeping in mind that only those
commands received after a HOLD and before a TRG (trigger) will be
released by the TRG command. In addition, only these commands
received after a supply disable (OVP or foldback protection) and before a
RST (reset) or OUT ON command will be released by the RST command
or the OUT command. Commands are executed in the order they are
received.
Command Syntax
3–5