Specifications For Xfr 2.8Kw With - Xantrex ENET-XFR Operating Manual

Internal ethernet and rs-232 interface for xfr series programmable dc power supplies
Table of Contents

Advertisement

Specifications

Specifications for XFR 2.8kW with

Interface
Installed
Table A-3 XFR 2.8kW 7.5 V to 40 V
M o d e l s
Program Resolution
Voltage
Current
OVP
a
Program Accuracy
Voltage
Current
OVP
Readback Resolution
Voltage
Current
a
Readback Accuracy
Voltage
Current
a. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model 20-130 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of
10 volts.
A–4
7 . 5 - 3 0 0
1 2 - 2 2 0
1.2mV
3.1mV
11.3mA
4.3mA
1.2mV
3.1mV
10mV
75mV
±0.12%
±0.12%
300mA
165mA
±0.15%
±0.15%
75mV
200mV
1.2mV
3.14mV
11.3mA
4.3mA
10mV
75mV
±0.12%
±0.12%
300mA
165mA
±0.15%
±0.15%
Ethernet/RS-232
2 0 - 1 3 0
3 3 - 8 5
5.1mV
5.1mV
2.6mA
13.0mA
5.1mV
5.1mV
75mV
75mV
±0.12%
±0.3%
120mA
425mA
±0.15%
±0.1%
330mV
330mV
5.1mV
5.1mV
2.6mA
13.0mA
75mV
75mV
±0.2%
±0.3%
120mA
425mA
±0.15%
±0.1%
4 0 - 7 0
6.2mV
2.2mA
6.2mV
75mV
±0.3%
110mA
±0.15%
400mV
6.2mV
2.2mA
75mV
±0.3%
110mA
±0.15%
TM-XR9B-01XN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Enet-xfr3

Table of Contents