Operation
3–18
Table 3-8 Accumulated Status, Status and Fault Registers
C o n d i t i o n
Constant voltage operation
Constant current operation
Not used
Overvoltage protection tripped
Over temperature protection tripped
Supply external shutdown active Pin 1 of the
user lines connector
Foldback mode operation
Remote programming error
Power ON
(accumulated status, status registers only)
Remote mode
(accumulated status, status registers only)
AC fail condition
Output fail condition
Sense protection tripped
Notes:
1.
All mnemonics can be masked or unmasked.
2.
The error (ERR) bit is reset in the accumulated status, status, and serial poll registers
with an error query (ERR?).
3.
The accumulated status register is cleared with an accumulated status query (ASTS?).
4.
A fault is cleared with a fault query (FAULT?).
B i t
M n e m o n i c
P o s i t i o n
CV
0
CC
1
–
2
OV
3
OT
4
SD
5
FOLD
6
ERR
7
PON
8
REM
9
ACF
10
OPF
11
SNSP
12
TM-XR9B-01XN
B i t
W e i g h t
1
2
4
8
16
32
64
128
256
512
1024
2048
4096