Table A-4 XFR 2.8kW 60 V to 600 V
M o d e l s
Program Resolution
Voltage
Current
OVP
a
Program Accuracy
Voltage
Current
OVP
Readback Resolution
Voltage
Current
a
Readback Accuracy
Voltage
Current
a. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model 20-130 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of
10 volts
TM-XR9B-01XN
Specifications for XFR 2.8kW with Ethernet/RS-232 Interface Installed
6 0 - 4 6
1 0 0 - 2 8
9.3mV
15.5mV
1.4mA
0.9mA
9.3mV
15.5mV
150mV
150mV
±0.3%
±0.35%
80mA
80mA
±0.1%
±0.1%
600mV
1.0V
9.3mV
15.5mV
1.4mA
0.9mA
150mV
150mV
±0.3%
±0.35%
80mA
80mA
±0.1%
±0.1%
1 5 0 - 1 8
3 0 0 - 9
23.2mV
46.4mV
0.6mA
0.3mA
23.2mV
46.4mV
225mV
225mV
±0.35%
±0.35%
80mA
75mA
±0.1%
±0.1%
1.5V
3.0V
23.2mV
46.4mV
0.6mA
0.3mA
225mV
225mV
±0.35%
±0.35%
80mA
75mA
±0.1%
±0.1%
6 0 0 - 4
92.7mV
0.2mA
92.7mV
300mV
±0.35%
75mA
±0.1%
6V
92.7mV
0.2mA
300mV
±0.35%
75mA
±0.1%
A–5