System Alarm Setup - NEC ASPILA EX Feature Manual

Hide thumbs Also See for ASPILA EX:
Table of Contents

Advertisement

Program 90 : Maintenance Program

90-10 : System Alarm Setup

90-10 : System Alarm Setup
Level:
IN
Description
Input Data
Default
Alarm
Type
Report
1
2 (MIN)
2
2 (MIN)
3
2 (MIN)
4
2 (MIN)
1038
Programming
Available.
Use Program 90-10 : System Alarm Setup to assign a status to system alarms. You can designate
an alarm as Major or Minor. This program also assigns whether or not the alarm is displayed to a
key telephone and whether or not the alarm information is reported to the pre-defined destination.
Alarm Number
Item No.
01
Alarm Type
02
Report
Note
0
Board Initialization
Error
0
Board Initial Test
Error
0
Board Installation
Error
0
Communication Error
Between Board and
NTCPU
Aspila EX
Item
Is Used To
Advise of . . .
Initialization failure or the
PCB is defective.
PCB initial test failure or the
PCB is defective.
PCB was unplugged without
using the proper procedure.
PCB communication failure
has occurred.
001-100
Input Data
0- Not set
1- Major Alarm
2- Minor Alarm
0- Not report (No auto-dial)
1- Report (auto-dial)
Action
Remove and reinstall the PCB.
If RECover message is received
in the alarm report, the PCB is
good. If not, replace with a new
PCB.
Remove and reinstall the PCB.
If RECover message is received
in the alarm report, the PCB is
good. If not, replace with a new
PCB.
Check the PCB installation.
Remove and reinstall the PCB.
If RECover message is received
in the alarm report, the PCB is
good. If not, replace with a new
PCB.
Aspila EX Software Manual