Toshiba e-STUDIO200L/230/280 SERIES Service Manual page 276

Table of Contents

Advertisement

[E]
Fuser roller
(1)
Take off the center heater lamp and side
heater lamp
(
P.13-12 "[D] Heater lamp").
(2)
Take out the fuser roller upward.
Notes:
1. When installing the fuser roller, move the
bearings on both ends outward so that
the bearings will be engaged into the
frames.
2. Be careful not to deform the fuser roller
by pushing strongly.
(3)
Remove 1 C-ring and 1 bearing from the
fuser roller front side.
(4)
Remove 1 C-ring, 1 gear and 1 bearing from
the fuser roller rear side.
[F]
Pressure roller
(1)
Take off the fuser roller
(
P.13-14 "[E] Fuser roller").
(2)
Place the fuser unit with the pressure roller
on its bottom. Remove 2 screws and take off
the fuser unit entrance guide.
e-STUDIO200L/230/280 FUSER UNIT
Bearing
Bearing
C-ring
13 - 14
Fuser roller
Bearing
Fig.13-16
C-ring
Gear
Bearing
Fig.13-17
Fuser unit entrance guide
Fig.13-18
June 2004 © TOSHIBA TEC