Remove the pulley, one-way clutch and 3 E-
rings. Then take off the pickup roller.
[R] Drawer feed clutch
(1)
Take off the drawer feeding unit
(
P.9-20 "[K] Drawer feeding unit").
(2)
Disconnect the connector and release the
harness from the harness clamp.
(3)
Remove 2 screws and take off the clutch
bracket and bushing.
Note:
Match the protruding portion of the clutch
with the position shown in the figure for
assembling.
June 2004 © TOSHIBA TEC
E-ring
Pickup roller
Fig.9-39
Fig.9-40
Clutch bracket
Fig.9-41