Program
Program Name
No.
12-07-01
Text Data for Night Mode - Text Message
12-08-01
Night Mode Service Range - Range
12-08-02
Night Mode Service Range - Lamp setting of tog-
gle key
20-01-17
System Options - Day/Night Change Key Mode
15-07-01
Programmable Function Keys - Programmable
Function Keys
11-10-01
Service Code Setup (for System Administrator) -
Night Mode Switching
11-10-50
Service Code Setup (for System Administrator) -
Night-mode Skip (Own Group)
20-07-01
Class of Service Options (Administrator Level) -
Manual Night Service Enabled
11-12-43
Service Code Setup (for Service Access) - An-
swer No-Ring Line (Universal Answer)
15-06-01
Trunk Access Map for Extensions - Trunk Ac-
cess Map Number
20-06-01
Class of Service for Extensions - Class of Serv-
ice for Extensions
20-10-07
Class of Service Options (Answer Service) - Au-
tomatic Off-Hook Answer
22-04-01
Incoming Extension Ring Group Assignment -
Extension Number
31-05-01
Universal Night Answer/Ring Over Page - Univer-
sal Night Answer/Ring
11-10-12
Service Code Setup (for System Administrator) -
Night Mode Switching for Other Group
14-07-01
Trunk Access Map Setup - Access Map
Features and Specifications Manual
Input Data
Maximum 12 Characters (alpha-
betic or numeric)
2 ~ 8
0 = Off
1 = On
0 = Toggle (Will follow PRG
12-08-01.)
1 = Skip (When pressed the sys-
tem will step to the next night
mode time period in PRG 12-02.)
09 = Night Mode Service key
0~9,
, # Maximum of 8 digit
*
0~9,
, # Maximum of 8 digit
*
0 = OFF (User cannot control
manual night mode.)
1 = ON (User can control manual
night mode.)
0~9,
, # Maximum of 8 digit
*
001 ~ 128
1 ~ 15
0 = Off
1 = On
Maximum eight Digits
0 = No Ringing (No)
1 = Ringing (Yes)
0~9,
, # Maximum of 8 digit
*
0 = No access
1 = Outgoing access only
2 = Incoming access only
3 = Access only when trunk on
Hold
4 = Outgoing access and access
when trunk on Hold
5 = Incoming and access when
trunk on Hold
6 = Incoming and outgoing ac-
cess
7 = Full access
SL2100
Default
Mode 1 = No Setting
Mode 2 = <Night>
Mode 3 = <Mid-night>
Mode 4 = <Rest>
Mode 5 = <Day2>
Mode 6 = <Night2>
Mode 7 = <Midnight2>
Mode 8 = <Rest2>
2
0
0
Refer to the program-
ming manual for the
default values and for
all other available op-
tions in this command.
718
787
COS 1 ~ 15 = 1
#9
1
Extension 101 is Class
15 and other Extension
are Class 1
COS 01 ~ 15 = 0
Group01 has 101, 102,
103, 104, 105, 106,
107, and 108 (First 8
ports ringing)
0
618
Access Map 1~128 =
Trunk Ports 1~128 as-
signed with option 7 ac-
cess (incoming and
outgoing access and
access when trunk is
on Hold).