Intervals - Beckhoff AG3210 Operating Instructions Manual

Economy planetary gear unit
Table of Contents

Advertisement

Maintenance and cleaning

Intervals

10.2
Component
Interval
Gear unit
During commission-
ing
Thereafter:
Every three months
Clamping screw
During commission-
Motor attachment
ing
Thereafter:
Every three months
Fastening screw
During commission-
Gear unit housing
ing
Thereafter:
Every three months
Ball bearing
20000 operating
hours
Lubrication
10.2.1
58
───
Under nominal conditions, the motor components have different op-
erating hours. We have provided you with a list of maintenance work
and intervals for the associated components below:
Maintenance
Check gear unit for external damage and leaks
Check drive shaft and output shaft for foreign media such as oil
and dirt
Check gear unit for corrosion
Check tightening torques
Check tightening torques
Replace bearing
Notes on lubrication
Beckhoff gear units from the AG3210 series are lubricated for life.
The lubricant used does not have to be renewed.
If you wish to change the lubricant, contact Beckhoff Service.
All gear units are lubricated for life with a lithium soap grease on a
mineral oil basis or with a food-safe synthetic lubricating grease con-
sisting of hydrocarbon oil and aluminum complex soap. Refer to the
name plate for detailed information on lubrication. All bearings are
lubricated for life at the factory.
Further information on the lubricants can be obtained directly from
the manufacturer:
Standard lubricants
Castrol Industrie GmbH
Mönchengladbach
Phone: +49 2161 909-30
www.castrol.com
AG3210
Lubricants for the food indus-
try, U SDA-H1 registered
Klüber Lubrication München KG
Munich
Phone: + 49 89 7876-0
www.klueber.com
Version: 2.2

Advertisement

Table of Contents
loading