Table 22. Error Codes For The Schwintek In-Wall Slide System - Tiffin Motorhomes VANLEIGH BEACON Owner's Manual

Table of Contents

Advertisement

2 12
For error codes, the
error code (see below).
red led error Code 
When an error code is present, the board needs to be reset. Energizing the extend/retract
switch resets the board. Energize the extend/retract switch again for normal operation.
checking fuses
The IN-WALL slide system requires a minimum of 30-amp fuse. Check the fuse box (lo-
cated in the command center) for blown fuses, and replace as necessary. If the fuse blows
immediately upon replacement, there may be a problem with the wiring to the control box
(contact your dealer for assistance).
Low voltage
The IN-WALL slide controller is capable of operating the electric slide room with as little as
8-volts. But at these lower voltages the amperage requirement is greater. Check the voltage
at the controller; if the voltage is lower than 11-volts, it is recommended that the auxiliary
battery be placed on a charger until it is fully charged.
only one (1) side moving
The IN-WALL slide system has a separate motor to operate each side of the room. If only
one side of the room moves a short distance (2 to 4 inches) and stops:
Will the non-moving side move with help?
If only one (1) side of the room is moving, then with someone's assistance press the
switch to extend or retract the room while pushing the non-moving side in the appro-
priate direction. On larger rooms it may be necessary to have two (2) or more people
pushing the room.
2 1 2
s li d eo u T sYsTe Ms
RED LED
will blink between two and nine (2-9) times to indicate the
Table 22. Error Codes for the Schwintek In-Wall Slide System
Battery drop out; battery capacity low enough to drop below 6
volts while running. 
Low battery; voltage below 8 volts at start of cycle. 
High battery; voltage greater than 18 volts. 
Excessive motor current; high amperage, also indicated by one
(1) side of slide continually stalling. 
Motor short circuit; motor or wiring to motor has shorted out. 
Hall signal not present; encoder is not providing a signal. 
Hall power short; power to encoder has been shorted to ground.
Usually a wiring problem. 
VA N L E I G H B E A c o N