Troubleshooting The Schwintek In-Wall Slide System; Figure 120. Disengaging The Slide Motors - Tiffin Motorhomes VANLEIGH BEACON Owner's Manual

Table of Contents

Advertisement

Disengage motors, manually retract room and travel lock:
1.
On the outside of the slide, Locate and remove motor retention screw located near
the top of each vertical column on the side.
Slide Motor (Outside)

Figure 120. Disengaging the Slide Motors

2.
On the inside of the slide, bend back the wipe seal and visually locate motor.
3.
Pull the motor up until disengaged, about
hold the motor in this position.
4.
Repeat this process for both sides of the slide room.
5.
Push or pull the slide room back in to the opening, keeping the side of the slide
room relatively even.
6.
Re-engage motor to be ready for travel.
TRoUBLESHo oTING THE ScHWINTEK IN - WALL SLIDE SYSTEM
Error codes
During operation, when an error occurs the board will use the LEDs to indicate where the
problem exists.
For motor specific faults, the
tor 2.
s li d eo u T sYsTe Ms
Motor Retention Screw
Slide Motor (Inside)
˝. Replace the motor retention screw to
1
2
GREEN LED
will blink once for motor 1, and twice for mo-
VA N L E I G H B E A c o N
2 1 1
2 1 1

Advertisement