4.0 Rigging Procedures
4.6 Ground Stacking IS10
5. Position the Rigging Frame over the IS119,
lining each corner rigging link of the Rigging
Frame with the sides of the IS119.
6. 2x T45 screws per corner connect each rigging
link to the IS119. Use torque setting of 6.5 Nm.
Adamson Systems Engineering | IS-Series Rigging Manual