Ground Stacking Is7 - Adamson IS Series Rigging Manual

Line array
Hide thumbs Also See for IS Series:
Table of Contents

Advertisement

4.0 Rigging Procedures

4.3 Ground Stacking IS7

1. Remove all Quick Release L-Handles and the 2
Lifting Plates from the IS7/IS118 Rigging Frame
and place them in a secure place for future use.
2. Designate 1 IS7 to be the top cabinet for your
stack. Remove the T25 Torx screws and rear
rigging links from the rear rigging piece of this
cabinet.
3. With the T25 Torx screws removed earlier,
attach the rigging links, lining up the X hole of the
rigging link to the top hole of the Rigging Frame.
Torque setting of 6.5 Nm is to be used.
4. Lower the 4x Rigging Frame rigging links on
each corner of the Rigging Frame, removing and
loosening the T25 Torx screws as necessary.
Adamson Systems Engineering | IS-Series Rigging Manual