Description Of The Pump (Set); General Description; Product Information As Per Regulation No. 547/2012 (For Water Pumps With A Maximum Shaft Power Of 150 Kw) Implementing "Ecodesign" Directive 2009/125/Ec; Designation - Speck pumpen Normblock Installation & Operating Manual

Closed-coupled pump
Table of Contents

Advertisement

Available languages

Available languages

4 Description of the Pump (Set)

4 Description of the Pump (Set)

4.1 General description

▪ Centrifugal pump with shaft seal
▪ Close-coupled design
Pump for handling clean or aggressive fluids which are neither chemically nor
mechanically aggressive to the pump materials.
4.2 Product Information as per Regulation No. 547/2012 (for water pumps
with a maximum shaft power of 150 kW) implementing "Ecodesign"
Directive 2009/125/EC
▪ Minimum efficiency index: see name plate, key to name plate
▪ The benchmark for the most efficient water pumps is MEI ≥ 0.70.
▪ Year of construction: see name plate, key to name plate
▪ Manufacturer's name or trade mark, commercial registration number and place
of manufacture: see order documentation
▪ Product's type and size identificator: see name plate, key to name plate
▪ Hydraulic pump efficiency (%) with trimmed impeller: see order documentation
▪ Pump performance curves, including efficiency characteristics: see documented
characteristic curve
▪ The efficiency of a pump with a trimmed impeller is usually lower than that of a
pump with full impeller diameter. Trimming of the impeller will adapt the pump
to a fixed duty point, leading to reduced energy consumption. The minimum
efficiency index (MEI) is based on the full impeller diameter.
▪ Operation of this water pump with variable duty points may be more efficient
and economic when controlled, for example, by the use of a variable speed drive
that matches the pump duty to the system.
▪ Information on dismantling, recycling and disposal after decommissioning:
(⇨ Section 3.5 Page 14)
▪ Information on benchmark efficiency or benchmark efficiency graph for
MEI = 0.70 (0.40) for the pump based on the model shown in the Figure are
available at:
http://www.europump.org/efficiencycharts

4.3 Designation

Example: Normblock 32/160 W12
Table 5: Key to the designation
Code
Normblock
32
160
W12
Normblock
Description
Type series
Nominal discharge nozzle diameter [mm]
Nominal impeller diameter [mm]
Material variant, e.g. W12