Installation Guide Linear Rotary Motors
8.6.1 Linear Motor PS01-37x120F-HP-R
Pin assignment
Phase 1+ / Phase 1-
Phase 2+ / Phase 2-
5V / GND
Sensor Sine / GND
Sensor Cosine / GND
Temp. Sensor / GND
Phase / GND
All Pins / Shield
8.6.2 Rotary Motor Stator RS01-52x40-R
Pin assignment
Phase A / Phase B
Phase A / Phase C
5V / GND
Sensor Sine / GND
Sensor Cosine / GND
Temp. Sensor / GND
Phase / GND
All Pins / Shield
8.6.3 Rotary Motor Stator RS01-52x60-R
Pin assignment
Phase A / Phase B
Phase A / Phase C
5V / GND
Sensor Sine / GND
Sensor Cosine / GND
Temp. Sensor / GND
Phase / GND
All Pins / Shield
9 Transport and Storage
•
LinMot linear rotary motors may only be transported and stored in their original packaging.
•
The motors should not be removed from the packaging until installation.
•
The storage room must be dry, dust-free, frost-free and vibration-free.
•
The relative air humidity should be less than 60 %.
•
Prescribed storage temperature: -15 °C...70 °C
•
Linear rotary motors must be protected against extreme weather conditions.
Page 42 / 48
Pins
Pin 1 / Pin 2
Pin 3 / Pin 4
Pin A / Pin B
Pin C / Pin B
Pin D / Pin B
Pin E / Pin B
Pin 1,2,3,4 / Pin B
Pin 1-E / Housing
Pins
Pin 1 / Pin 2
Pin 1 / Pin 3
Pin A / Pin B
Pin C / Pin B
Pin D / Pin B
Pin E / Pin B
Pin 1,2,3,4 / Pin B
Housing
Pins
Pin 1 / Pin 2
Pin 1 / Pin 3
Pin A / Pin B
Pin C / Pin B
Pin D / Pin B
Pin E / Pin B
Pin 1,2,3,4 / Pin B
Housing
PR01-52
ENG
Resistance @ 20 °C
2.6 Ω
2.6 Ω
155 Ω
33 kΩ
33 kΩ
10 kΩ
>20 MΩ
>20 MΩ
Resistance @ 20 °C
7.1
7.1
155
33 k
33 k
10 k
>20 M
>20 M
Resistance @ 20 °C
3
3
155
33 k
33 k
10 k
>20 M
>20 M
NTI AG / LinMot