Siemens NXPLUS C Installation And Operating Instructions Manual page 51

Medium-voltage switchgear, fixed-mounted circuit-breaker switchgear up to 24 kv, extendable, single busbar, metal-enclosed, gas-insulated
Table of Contents

Advertisement

Paper-insulated belted cables (non-draining cables) ≤ 12 kV (according to GOST 18410-73)
Cable type
3-core cable, paper-insulated
ASB and ASBL
Paper-insulated belted cables (mass-impregnated cables) ≤ 12 kV (according to IEC 60055 and VDE 0255)
Cable type
3-core cable, paper-insulated
NKBA (Cu), NKBY (Cu), NKRA
(Cu) and NKFA (Cu)
or
NAKBA (Al), NAKBY (Al),
NAKRA (Al) and NAKFA (Al)
Paper-insulated belted cables (mass-impregnated cables) ≤ 12 kV (according to GOST 18410-73)
Cable type
3-core cable, paper-insulated
ASB and ASBL
Commercially available bar systems
Bar type
Bar connection
Make
Solid-insulated
MGC Moser Glaser
busbars
Preissinger
Ritz
Make
Type
3M
SP 33
SP 33
Nexans Euromold
400DR-B
K400DR-B
nkt cables
CBC 40,5-630
CBC 40,5-630
Südkabel
SP 33
SP 33
Cellpack
CIK
CIK
Ample
AJM-15/630
AJM-24/630
802-9081.9 • INSTALLATION AND OPERATING INSTRUCTIONS • NXPLUS C • Revision 11
Cable sealing end
Make
Type
Nexans Euromold
430TB/G
nkt cables
CB 24-630
Cable sealing end
Make
Type
nkt cables
CB 24-630
Cable sealing end
Make
Type
nkt cables
CB 24-630
Type
Conductor material
Duresca DE
Copper
Duresca DG
Copper
ISOBUS MB
Copper
SIS
Copper
Surge-proof caps
Size
Outside cone type "C"
Outside cone type "C"
Outside cone type "C"
Outside cone type "C"
Outside cone type "C"
Outside cone type "C"
Outside cone type "C"
Outside cone type "C"
Outside cone type "C"
Outside cone type "C"
Outside cone type "C"
Outside cone type "C"
Remark
2
Cross-section [mm
]
35...300
EPDM with conductive layer, in combination
with distribution kit MIND
25...240
Silicone with conductive layer (optionally
with metal housing), in combination with
transition sealing end type SÜEV 10
Remark
2
Cross-section [mm
]
25...240
Silicone with conductive layer (optionally
with metal housing), in combination with
transition sealing end type SÜEV 10
Remark
2
Cross-section [mm
]
25...240
Silicone with conductive layer (optionally
with metal housing), in combination with
transition sealing end type SÜEV 10
Maximum rated current
1250 A / 2500 A
1250 A / 2500 A
1250 A / 2500 A
1250 A / 2500 A
Rated voltage
12 kV
24 kV
12 kV
24 kV
12 kV
24 kV
12 kV
24 kV
12 kV
24 kV
12 kV
24 kV
Description
Remark
Outer sheath made of polyamide
(polyamide tube)
Outer sheath made of CrNi steel or
aluminum (metal sheath)
Outer sheath made of epoxy resin
(with heat shrinkable tube, if
required)
Outer sheath made of epoxy resin
(with heat shrinkable tube, if
required)
Remark
Silicone with semi-conductive layer
EPDM with semi-conductive layer
Silicone with semi-conductive layer
Silicone with semi-conductive layer
EPDM with semi-conductive layer
EPDM with semi-conductive layer