Siemens NXPLUS C Installation And Operating Instructions Manual page 37

Medium-voltage switchgear, fixed-mounted circuit-breaker switchgear up to 24 kv, extendable, single busbar, metal-enclosed, gas-insulated
Table of Contents

Advertisement

Circuit-breaker panel 630 A, 1000 A ● Switch-disconnector panel 630 A ● Disconnector panel 1000 A ● Ring-main panel 630 A ● Vacuum
contactor panel ● Circuit-breaker panel with top-rear cable connection 1250 A
Panel spacing 600 mm
Make
Conductor
cross-
2
section
2
[mm
]
Cellpack
50...400
EPDM
25...300
50...240
EPDM
25...240
Ample
25...400
EPDM
35...500
3 cables per panel and phase
Nexans
35...300
EPDM
Euromold
35...300
EPDM
50...630
EPDM
35...630
800...1200
EPDM
nkt cables 25...300
Silicon
e
25...500
25...300
185...500
Silicon
e
95...500
400...630
Silicon
e
630...1000
Silicon
e
Tyco
25...300
Silicon
Electronics
e
Raychem
25...300
Silicon
e
400...800
Silicon
e
400...800
Silicon
e
Cellpack
50...240
EPDM
25...240
1
At a continuous current of more than 1150 A, cable sealing ends with tin-plated, nickel-plated or silver-plated cable lugs are required.
2
Observe the actual current- and short-circuit-carrying capacity of the cables and sealing ends.
802-9081.9 • INSTALLATION AND OPERATING INSTRUCTIONS • NXPLUS C • Revision 11
Cable T-plugs
Coupling inserts/
coupling plugs
bolted
bolted
12 kV
12 kV
24 kV*
24 kV*
2x CTS 630A 24kV
1x CKS 630A 24kV
2x CTS 630A 24kV*
1x CKS 630A 24kV*
1x CTS 630A 24kV
1x CTKS 630A 24kV
1x CTS 630A 24kV*
1x CTKS 630A 24kV*
1x AQT3-15/630
1x AHT3-15/630
1x AQT3-24/630*
1x AHT3-24/630*
1x 430TB/G
2x 300PB/G
1x K430TB/G*
2x K300PB/G*
1x K430TB/G-CSxxx*
2x K300PB/G-CSxxx*
1x 480TB/G
2x 800PB/G
1x K480TB/G*
2x K800PB/G*
1x 484TB/G
2x 804PB/G
1x K484TB/G*
2x K804PB/G*
1x 489TB/G
2x 809PB/G
1x K489TB/G*
2x K809PB/G*
1x CB 12-630
2x CC 12-630
1x CB 17,5-630
2x CC 17,5-630
1x CB 24-630*
2x CC 24-630*
1x CB 24-1250-2
2x CC 24-1250-2
1x CB 24-1250-2*
2x CC 24-1250-2*
1x CB 36-630(1250)
2x CC 36-630(1250)
1x CB 36-630(1250)* 2x CC 36-630(1250)*
1x CB 42-1250-3
2x CC 42-2500-3
1x CB 42-1250-3*
2x CC 42-2500-3*
1x RSTI-58xx
2x RSTI-CC-58xx
1x RSTI-58xx*
2x RSTI-CC-58xx*
1x RSTI-58xx-CEE01
2x RSTI-CC-58xx-CEE01
1x RSTI-58xx-CEE01*
2x RSTI-CC-58xx-CEE01*
1x RSTI-395x
2x RSTI-CC-395x
1x RSTI-595x*
2x RSTI-CC-595x*
1x RSTI-595x-CEE01
2x RSTI-CC-595x-CEE01
1x RSTI-595x-CEE01*
2x RSTI-CC-595x-CEE01*
1x CTS 630A 24kV
2x CTKS 630A 24kV
1x CTS 630A 24kV*
2x CTKS 630A 24kV*
1
Surge arresters with coupling inserts
with arresters
Coupling inserts
additionally
-
-
CTKSA
CTKSA
AHY5WZ7
AHY5WZ7
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Description
According to
standard
• GOST
(Russia, CIS)
• GB/DL (China)
-
IEC
-
IEC
-
IEC
-
IEC
-
GB/DL
-
GB/DL
-
IEC, GOST, GB/DL
-
IEC
-
GOST, GB/DL
-
IEC
-
IEC
-
IEC
-
IEC
-
IEC
-
IEC
-
IEC
-
GOST, GB/DL
-
IEC, GOST, GB/DL
-
IEC
-
IEC
-
IEC, GOST, GB/DL
-
IEC, GOST, GB/DL
-
IEC
-
IEC
-
IEC
-
IEC
-
GOST
-
GOST
-
IEC
-
IEC
-
GOST
-
GOST
-
IEC
-
IEC
37/293

Advertisement

Table of Contents
loading

Table of Contents