Chapter 9 Technical specifications
Environment
Environment
Temperature
Humidity
Climatic
pressure
EMI/ESD
Electrical
Safety
Drop test
Shocks
Bumps
72
–
Operating temperature range
–
Operation including all options
(guaranteed specifications)
–
Storage
–
5 to 95% without condensation
–
Climatic pressure: 4000 meters
–
CE class B Compliant (EN61326-1)
–
FCC 47-1 Part 15 Compliant
–
EN 61010-1: 2001 Compliant
In accordance with the Telcordia GR-196-CORE recommendations, the
2000 Platform resists the following test:
–
6 impacts dropped from a height of 1m on a pinwood floor of 5 cm
thickness (1 impact on each of its 6 sides, with power off).
The 2000 Platform resists the following test:
–
3 shocks per axis along each of the 3 axes, with power off.
–
Impacts of 15g, 1/2 sine, duration 11 ms, at 10 second intervals.
The 2000 Platform resists the following test:
–
1,000 bumps per axis along each of the 3 axes, with power off.
–
Jolts of 15g, 1/2 sine, duration 6 ms, at 1 second intervals.
User Manual
790000002/00
-20°C to +50°C (-4°F to +122°F)
0° to +40°C (+32°F to +104°F)
-20C to +60C (-4°F to +140°F)