5-2 Setting③: UART Communication Setting
Address
Register name
7004h
BaudRateSelect R/W
7008h
ContTimeOut
5-2-5 UART Communication Setting
[Function]
UAER communication in Camera Link®
1) Switch baud rate
2) Setting time of time out
1) Switch baud rate for UART communication
It is able to select from 9.6kbps/19.2kbps/115.2kbps.
Initial value is 9.6kbps.
2) Setting time of time out for UART communication
Setting the time which is able to resume to receive the
command if sending incorrect command and no reply from
CIS.
Initial value is 30 seconds(Parameter Data = 150).
TM-XJ959A
R/W
Parameter
Data
Switch baud rate of UART communication in Camera Link®
0 to 2
0: 9.6kbps, 1: 19.2kbps, 2: 115.2kbps
Setting time of time out for UART communication in
R/W
0 to 65535
Camera Link®
0:Disable, 1:0.2seconds afterwards every 0.2seconds
Camera Link® is a trade mark registered by AIA(Automated Imaging Association).
Function
UART Specification
Item
Baud Rate
9.6kbps,19.2kbps,115.2kbps
Data bit
Parity
Start bit
Stop bit
Flow Control
【Remarks】
1) Ignore return data from CIS due to change communication
baud rate. Because communication baud rate is changed
immediately on receiving this command and return data of this
command is send by the changed baud rate from CIS.
2) When using the UserSet _ # _ Save command, set the
TimeOut time back to the initial value. If time out time is shorter
than 30 seconds, error is happened when executing
UserSet_#_Save command and be not able to save the setting
data.
Initial
0
150
Function
8
None
1
1
none
70
© Mitsubishi Electric Corporation